ProTeam Inspections, Inc.
PO Box 2379
|
|||
Customer |
|||
Location |
|||
Real Estate Agent |
|||
|
|||
Report ID: |
|||
Inspection Date
|
|||
Inspected By
|
|||
ProTeam Inspections, Inc. Agreement for Home Inspection Services
|
Client: |
Home Buyer |
Date: |
Friday, August 15, 2003 |
|
Address: |
2121 My New Home Place Jacksonville, Fl 32202 |
Fee: |
225.00 |
For and in consideration of the terms of this Agreement for Home Inspection Services the Inspector and Client agree:
|
__________________________________ |
__________________________________ |
|
INVOICE |
| ProTeam Inspections, Inc.
PO Box 2379 Orange Park, Florida 32067-2379 904-278-6694 Inspected By: Frank Woodward-ASHI 207851 |
Inspection Date: Friday, August 15, 2003
Report ID: PRI081503 |
| Customer Info: | Inspection Property: |
| Home Buyer
Customer's Real Estate Professional: |
2121 My New Home Place Jacksonville, Fl 32202 |
Inspection Fee:
| ||||||||
Tax $0.00 | ||||||||
| Total Price $225.00 |
| Payment Options: |
|
The home inspector shall observe: Roof covering; Roof drainage systems; Flashings; Skylights, Chimneys, and roof penetrations; and Signs of' leaks or abnormal condensation on building components.The home inspector shall: Describe the type of roof covering materials; and Report the methods used to observe the roofing.The home inspector is not required to: Walk on the roofing; or Observe attached accessories including but not limited to solar systems, antennae, and lightning arrestors.
| VIEWED ROOF FROM: WALKED ROOF | ROOF-TYPE: GABLE HIP | ROOF COVERING: 3-TAB FIBERGLASS |
| VENTILATION: SOFFIT VENTS OFF-RIDGE VENT | CHIMNEY: WOOD |
| 1.0 | ARE THERE ANY NOTICEABLE SWAYS OR SAGS IN THE ROOF SHEATHING
Comments: No |
| 1.1 | ARE THERE MULTIPLE LAYERS OF ROOF COVERINGS
Comments: No |
| 1.2 | DOES THE ROOF COVERING APPEAR TO BE IN SERVICEABLE CONDITION
Roof covering is nearing the end of it's life cycle at the "entire roof". Roof covering will need replacing before 5 years. Roof has several missing shingles at rear of roof. Shingles are beginning to curl at edges. Area of roof left of fireplace chase has been repaired. (picture-2) Check with seller for cause. |
| 1.3 | IS DRIP EDGE INSTALLED ALONG ROOF PERIMETER
Comments: Yes |
| 1.4 | FLASHINGS
Chimney is not flashed properly. Chimney flashing has been placed over surface of siding and caulked. This area will need periodical maintenance. (picture-1) Neoprene flashings around plumbing stacks are worn and require replacing (picture-2). Roof sheathing is discolored around pipe penetrations in attic area. (picture-3) |
| 1.5 | ROOF VENTILATION
Soffit vent screen deteriorated at front of home. |
| 1.6 | SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS
Trim boards at rear of chimney flashing are loose. (picture-1) Wood rot was found at roof level of fireplace chase on right and left sides. This is the result of incorrect flashings (no kickout flashings) at the fireplace chase. (picture-2) Wood rot was found at the back of the fireplace chase just above the Z-flashing joint. (picture-3) |
The home inspector shall observe: Wall cladding, Flashings, and Trim; Eaves, Soffits, and Fascias; The home inspector shall: Describe wall cladding materials; Probe exterior wood components where deterioration is suspected. The home inspector is not required to: Move personal items, panels, furniture, equipment, plant life, soil, snow, ice or debris that obstructs access or visibility.
| SIDING STYLE: LAP T-111 BRICK | SIDING MATERIAL: WOOD CEMENT-FIBER COMPOSITE BOARD BRICK VENEER | FOUNDATION TYPE: SLAB ON GRADE |
| EAVES MATERIAL: WOOD |
| 2.0 | CONDITION OF SOFFIT, FASCIA, TRIM AND EAVES
Comments: INSPECTED |
| 2.1 | CONDITION OF EXTERIOR WALL COVERINGS
Wood deteriation (wood rot) found as follows: picture 1- Front elevation left side of garage- lap siding above hardy board siding. picture 2- Front elevation right of front door-bottom lap siding above brick sill and widow frame trim boards picture 3- Front elevation left and right areas at front entrance. picture 4- Front elevation left of front entrance-lap siding above brick sill and bottom of window trim. Bottom lap siding behind plants in corner. picture 5- Rear elevation-bottom of right rear window trim board. picture 6- Rear elevation-left bottom corner of door trim. picture 7- Rear elevation-siding has wood rot at bottom at left corner area. picture 8- Hole in wood siding at left side of fireplace chase should be sealed. |
| 2.2 | FOUNDATION WALLS AND MORTAR JOINTS (exterior)
Foundation footer is exposed at right elevation. Advise to add 6-8 inches of soil . |
The home inspector shall observe Entryway doors and a representative number of windows. Operate all entryway doors and a representative number of windows. The home inspector is not required to observe: Storm windows, storm doors, screening, shutters, awnings, and similar seasonal accessories; Presence of safety glazing in doors and windows.
| ENTRY DOORS: STEEL | INTERIOR DOORS: HOLLOW CORE | WINDOWS: METAL |
| WINDOW TYPES: SINGLE-HUNG |
| 3.0 | OUTSIDE APPEARANCE OF WINDOWS OR SKYLIGHTS
Comments: INSPECTED Missing screens |
| 3.1 | CONDITION OF EXTERIOR ENTRY DOORS
Comments: INSPECTED Rear door rubs carpet. |
| 3.2 | IS DOOR CHIME OPERATIONAL
Comments: Yes |
The home inspector shall observe: Garage door operators; Operate garage doors manually or by using permanently installed controls for any garage door operator; Report whether or not any garage door operator will automatically reverse or stop when meeting reasonable resistance during closing. The home inspector is not required to observe: Garage door operator remote control transmitters.
| GARAGE DOOR MATERIAL: METAL | TYPE: ONE AUTOMATIC |
| 4.0 | GARAGE DOOR OPERATORS
Comments: INSPECTED |
| 4.1 | DOES THE GARAGE DOORS "REVERSE" WITH RESISTANCE
Comments: Yes |
| 4.2 | CONDITION OF GARAGE DOOR
Comments: INSPECTED Garage door has minor bend to top panel rib causing door to bow out. |
The home inspector shall observe: vegetation, grading, drainage, driveways, patios, walkways, and retaining walls with respect to their effect on the condition of the building. The home inspector is not required to observe: Fences; Geological conditions; Soil conditions; Recreational facilities (including spas, saunas, steam baths, swimming pools, tennis courts, playground equipment, and other exercise, entertainment, or athletic facilities); Detached buildings or structures; or Presence or condition of buried fuel storage tanks.
| DRIVEWAY: CONCRETE |
| 5.0 | DOES LANDSCAPE FAVOR PROPER DRAINAGE
Comments: Yes |
| 5.1 | WALKWAY AND DRIVEWAY
Visible settlement cracks at driveway and rear patio. |
The home inspector shall observe: Insulation and vapor retarders in unfinished spaces; Ventilation of attics and foundation areas; Kitchen, bathroom, and laundry venting systems; and the operation of any readily accessible attic ventilation fan, and, when temperature permits, the operation of any readily accessible thermostatic control. The home inspector shall describe: Insulation in unfinished spaces; and Absence of insulation in unfinished space at conditioned surfaces.The home inspector is not required to report on: Concealed insulation and vapor retarders; or Venting equipment that is integral with household appliances. The home inspector is not required to disturb insulation except when readily visible evidence indicates the need to do so; and Move insulation where chimneys penetrate roofs.
| ATTIC INFO: SCUTTLE HOLE | ||
| INSULATION: BLOWN BATT FIBERGLASS | R- VALUE: R-19 OR BETTER | ROOF STRUCTURE: ENGINERED WOOD TRUSS |
| CEILING STRUCTURE: 2X4 |
| 6.0 | IS THERE AN ATTIC ACCESS
Comments: Yes |
| 6.1 | IS INSULATION IN ATTIC
Fiberglass (Batts) insulation is about six inches thick or just under 19 R-Value. Fiberglass (loose-fill) insulation is about six inches thick or just under 19 R-Value. Batt insulation displaced at living room knee wall. |
| 6.2 | DOES RAFTERS APPEAR TO BE IN GOOD CONDITION
Comments: Yes |
| 6.3 | ARE THERE ANY VISIBLE SIGNS OF LEAKS OR ABNORMAL CONDENSATION
Comments: INSPECTED Water signs on plywood resulting from a "Roof leak" found around plumbing exhaust pipe. Recommend repair or replace flashings as needed. |
| 6.4 | IS THERE CROSS-VENTILATION
Comments: Yes |
| 6.5 | ARE THERE ANY VISIBLE SIGNS OF DETERIORATION
Comments: No |
| 6.6 | ARE THERE ANY DEBRIS IN ATTIC
Personal items still remain in Attic. |
| 6.7 | ARE THERE ANY UNSAFE ELECTRICAL WIRING IN ATTIC
Comments: No |
The home inspector shall observe: Walls, ceiling, and floors; and a representative number of doors and windows. The home inspector shall: Operate a representative number of windows and interior doors. The home inspector is not required to observe: Paint, wallpaper, and other finish treatments on the interior walls, ceilings, and floors; Carpeting; or Draperies, blinds, or other window treatments; Move personal items, panels, furniture, equipment, plant life or debris that obstructs accerss or visibility.
| CEILING MATERIAL: SHEETROCK | WALL MATERIAL: SHEETROCK | FLOOR COVERING(S): VINYL |
| 7.0 | KITCHEN COMPLIMENTARY VIEW
Kitchen complimentary view. |
| 7.1 | CEILING
Comments: INSPECTED |
| 7.2 | WALLS
Comments: INSPECTED |
| 7.3 | FLOOR
Comments: INSPECTED |
| 7.4 | PANTRY OR CL0SET DOORS
Comments: INSPECTED |
| 7.5 | OUTLETS AND WALL SWITCHES CONDITION
Comments: INSPECTED GFCI receptacle left of kitchen sink was inoperative. Advise replacement. |
The home inspector shall observe Counters and a representative number of installed cabinets; and operate the basic functions of the following kitchen appliances: Permanently installed dishwasher, through its normal cycle; Range, cook top, and permanently installed oven; Trash compactor; Garbage disposal; Ventilation equipment or range hood; and Permanently installed microwave oven. The home inspector is not required to observe: Clocks, timers, self-cleaning oven function, or thermostats for calibration or automatic operation; Non built-in appliances; or Refrigeration units. The home inspector is not required to operate: Appliances in use; or Any appliance that is shut down or otherwise inoperable.
| CABINETRY: WOOD | COUNTERTOP: LAMINATE | DISHWASHER: GENERAL ELECTRIC |
| RANGE/OVEN: MAGIC CHEF | EXHAUST/RANGE: NUTONE | |
| REFRIGERATOR: ADMIRAL | DRYER VENT: DRAIN PIPE MATERIAL | DRYER POWER SOURCE: 22O ELECTRIC |
| 8.0 | KITCHEN FIXTURES AND APPLIANCES (over-all)
Comments: INSPECTED |
| 8.1 | CONDITION OF PLUMBING UNDER SINK
Comments: INSPECTED |
| 8.2 | ARE CUT-OFF VALVES UNDER SINK
Comments: Yes |
| 8.3 | FAUCET AND SPRAY NOZZLE CONDITION
Comments: INSPECTED Faucet is not working properly, and needs repair or replace. Faucet did not have an aerator and spray did not divert correctly. |
| 8.4 | IS DISPOSER OPERATIONAL
Comments: Yes |
| 8.5 | COOKTOP/OVEN OR RANGE OPERATIONAL
Comments: INSPECTED Right front burner inoperative |
| 8.6 | RANGE VENTILATION OPERATIONAL
Comments: No Fan would not operate |
| 8.7 | IS THE OUTLET FOR REFRIGERATOR 3 PRONG GROUNDED OR ACCESSIBLE
Comments: Yes |
| 8.8 | ARE THE OUTLETS WITHIN TWO FEET OF THE SINK GFCI
Comments: Yes GFCI outlet is defective (grounded, but wont trip with test-plug). |
| 8.9 | CABINETS CONDITION
Comments: INSPECTED All cabinet doors and drawers operated and functioning properly. |
| 8.10 | CONDITION OF COUNTERTOP
Comments: INSPECTED No visible damage found |
| 8.11 | IS DISHWASHER OPERATIONAL
Comments: Yes |
| 8.12 | WASHER/DRYER CONNECTIONS
Dryer vent is currently venting to interior of garage. It appears the original dryer vent to exterior was abandoned. This mat be due to a clog in vent pipe. |
| CEILING MATERIAL: SHEETROCK | WALL MATERIAL: SHEETROCK | FLOOR COVERING: CARPET |
| 9.0 | LIVING ROOM COMPLIMENTARY VIEW
Living Room complimentary view. |
| 9.1 | CEILING
Comments: INSPECTED |
| 9.2 | WALLS
Comments: INSPECTED |
| 9.3 | FLOORS
Comments: INSPECTED |
| 9.4 | WINDOWS
Comments: INSPECTED |
| 9.5 | OUTLETS AND WALL SWITCHES CONDITION
Comments: INSPECTED |
| CEILING MATERIAL: SHEETROCK | WALL MATERIAL: SHEETROCK | FLOOR COVERING: CARPET |
| CLOSET DOORS: HOLLOW CORE |
| 10.0 | CEILING
Comments: INSPECTED |
| 10.1 | WALLS
Comments: INSPECTED |
| 10.2 | FLOORS
Comments: INSPECTED |
| 10.3 | DOORS
Comments: INSPECTED Front bedroom and master bedroom doors require adjustment. |
| 10.4 | WINDOWS
Comments: INSPECTED |
| 10.5 | OUTLETS AND WALL SWITCHES CONDITION
Comments: INSPECTED |
| CEILING MATERIAL: SHEETROCK | WALL MATERIAL: SHEETROCK TILE | FLOOR COVERING: TILE |
| 11.0.A | CEILING
Comments: INSPECTED |
| 11.1.A | WALLS
Comments: INSPECTED |
| 11.2.A | FLOORS
Comments: INSPECTED |
| 11.3.A | DOORS
Comments: INSPECTED |
| 11.4.A | WINDOWS
Comments: INSPECTED |
| 11.5.A | ARE BATHROOM OUTLETS GFCI PROTECTED
Comments: Yes |
| CEILING MATERIAL: SHEETROCK | WALL MATERIAL: SHEETROCK | FLOOR COVERING: VINYL |
| 11.0.B | CEILING
Comments: INSPECTED |
| 11.1.B | WALLS
The tile surround in the hall bathroom was tested with a moisture meter. Elevated levels of moisture was found below the window on the entire back wall of the tub tile surround. Elevated moisture indicates water has found a path to the substrate behind tile. Substrate behind tile covering may be damaged. |
| 11.2.B | FLOORS
Comments: INSPECTED Vinyl has moisture stains along bathtub |
| 11.3.B | DOORS
Comments: INSPECTED |
| 11.4.B | WINDOWS
Comments: INSPECTED |
| 11.5.B | ARE BATHROOM OUTLETS GFCI PROTECTED
Comments: Yes |
| 12.0 | CONDITION OF SINK BASE AND CABINETRY
Comments: INSPECTED |
| 12.1 | CONDITION OF PLUMBING FIXTURES
Comments: INSPECTED Hall bath has minor chip in finish under soap dish. Master bath right sink has minor chip to finish. Advise repair. |
| 12.2 | ARE CUT-OFF VALVES UNDER SINK AND TOILET
Comments: Yes |
| 12.3 | DOES SINK PLUMBING OPERATE PROPERLY
Comments: Yes |
| 12.4 | SINK FAUCETS AND STOP VALVE
Comments: INSPECTED |
| 12.5 | DOES TOILET OPERATE PROPERLY
Comments: Yes |
| 12.6 | DOES SHOWER/BATH DRAIN PROPERLY
Comments: Yes |
| 12.7 | SHOWER AND TUB FAUCETS AND STOP VALVE
Comments: INSPECTED |
| 12.8 | CAULKING ALONG PERIMETER OF TUB/SHOWER AND FLOOR
Comments: INSPECTED Recommend maintaining caulk at top of tub surround with silicone caulk at all baths. |
The home inspector shall observe: Service entrance conductors; Service equipment, grounding equipment, main overcurrent device, and main and distribution panels; Amperage and voltage ratings of the service; Branch circuit conductors, their overcurrent devices, and the compatibility of their ampacities and voltages; The operation of a representative number of installed ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls; The polarity and grounding of all receptacles within six feet of interior plumbing fixtures, and all receptacles in the garage or carport, and on the exterior of inspected structures; The operation of ground fault circuit interrupters; and Smoke detectors. The home inspector shall describe: Service amperage and voltage; Service entry conductor materials; Service type as being overhead or underground; and Location of main and distribution panels. The home inspector shall report any observed aluminum branch circuit wiring. The home inspector shall report on presence or absence of smoke detectors, and operate their test function, if accessible, except when detectors are part of a central system. The home inspector is not required to: Insert any tool, probe, or testing device inside the panels; Test or operate any overcurrent device except ground fault circuit interrupters; Dismantle any electrical device or control other than to remove the covers of the main and auxiliary distribution panels; or Observe: Low voltage systems; Security system devices, heat detectors, or carbon monoxide detectors; Telephone, security, cable TV, intercoms, or other ancillary wiring that is not a part of the primary electrical distribution system; or Built-in vacuum equipment.
| ELECTRICAL CONDUCTORS: BELOW GROUND | PANEL CAPACITY: 150 AMP | PANEL TYPE: CIRCUITS |
| WIRING METHODS: ROMEX | BRANCH WIRE 15 and 20 AMP: COPPER | |
| 13.0 | SERVICE ENTRANCE CONDUCTORS
Comments: INSPECTED |
| 13.1 | SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS
Comments: INSPECTED |
| 13.2 | BOND WIRE FROM ELEC PANEL TO METAL PLUMBING
Comments: Yes |
| 13.3 | DOES THE METERBASE HAVE A GROUND WIRE AND ROD
Comments: Yes |
| 13.4 | CONDITION OF WIRING, CIRCUITS, OR FUSES INSIDE MAIN PANEL (Branch circuit conductors, Over-current devices, and compatibility of their amperage and voltage)
Comments: INSPECTED |
| 13.5 | ARE THE CIRCUITS OR FUSES LABELED CLEARLY
Comments: Yes |
| 13.6 | ARE THE CIRCUIT BREAKERS THE SAME BRAND NAME AS PANEL
Comments: Yes |
| 13.7 | LOCATION OF MAIN AND DISTRIBUTION PANELS
Main disconnect and distribution panel located in garage. |
| 13.8 | CONNECTED DEVICES, FIXTURES OR LOOSE WIRING (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls)
Comments: INSPECTED |
| 13.9 | POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 FEET OF INTERIOR PLUMBING FIXTURES, AND ALL RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF INSPECTED STRUCTURE
Comments: INSPECTED |
| 13.10 | OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS)
Comments: INSPECTED |
The home inspector shall observe: Interior water supply and distribution system, including: piping materials, supports, and insulation; fixtures and faucets; functional flow; leaks; and cross connections; Interior drain, waste, and vent system, including: traps; drain, waste, and vent piping; piping supports and pipe insulation; leaks; and functional drainage; Hot water systems including: water heating equipment; normal operating controls; automatic safety controls; and chimneys, flues, and vents; Fuel storage and distribution systems including: interior fuel storage equipment, supply piping, venting, and supports; leaks; and Sump pumps.The home inspector shall describe: Water supply and distribution piping materials; Drain, waste, and vent piping materials; Water heating equipment; and Location of main water supply shutoff device. The home inspector shall operate all plumbing fixtures, including their faucets and all exterior faucets attached to the house, except where the flow end of the faucet is connected to an appliance.The home inspector is not required to: State the effectiveness of anti-siphon devices; Determine whether water supply and waste disposal systems are public or private; Operate automatic safety controls; Operate any valve except water closet flush valves, fixture faucets, and hose faucets; Observe: Water conditioning systems; Fire and lawn sprinkler systems; On-site water supply quantity and quality; On-site waste disposal systems; Foundation irrigation systems; Spas, except as to functional flow and functional drainage; Swimming pools; Solar water heating equipment; or Observe the system for proper sizing, design, or use of proper materials.
| PLUMBING SUPPLY: PVC | DISTRIBUTION: COPPER | PLUMBING WASTE: PVC |
| WATER SOURCE: PUBLIC | WATER HEATER POWER SOURCE: ELECTRIC | |
| CAPACITY: 40 GAL (1-2 PEOPLE) | MANUFACTURER: A.O. SMITH |
| 14.0 | INTERIOR WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES
Comments: INSPECTED |
| 14.1 | INTERIOR DRAIN, WASTE AND VENT SYSTEMS
Comments: INSPECTED |
| 14.2 | ANY LEAKS OR CROSS-CONNECTIONS ON SUPPLY OR WASTE LINES
Comments: INSPECTED |
| 14.3 | FUNCTIONAL FLOW (water pressure and volume)
Comments: INSPECTED |
| 14.4 | WATER HEATER
Water heater located in garage |
| 14.5 | IS WATER HEATER WIRING SECURED PROPERLY
Comments: Yes |
The home inspector shall observe: Central air conditioning and permanently installed cooling systems including: Cooling and air handling equipment; and Normal operating controls. Distribution systems including: Fans, pumps, ducts and piping, with associated supports, dampers, insulation, air filters, registers, fan-coil units; and The presence of an installed cooling source in each room. The home inspector shall describe: Energy sources; and Cooling equipment type. The home inspector shall operate the systems using normal operating controls. The home inspector shall open readily openable access panels provided by the manufacturer or installer for routine homeowner maintenance The home inspector is not required to: Observe window air conditioners; or Operate cooling systems when weather conditions or other circumstances may cause equipment damage; Observe non-central air conditioners; or Observe the uniformity or adequacy of cool-air supply to the various rooms.
| NUMBER OF A/C UNITS: ONE | CENTRAL AIR MANUFACTURER: GOODMAN |
| 15.0 | THERMOSTATS CONDITION
Comments: INSPECTED |
| 15.1 | COOLING AND AIR HANDLER EQUIPMENT
Ambient air test was performed by using thermometers on air handler of Heat pump in cool mode to determine if the difference in temperatures of the supply and return air are between 14 degrees and 22 degrees which indicates unit is cooling as intended. The supply air temperature on your system read 65 degrees, and the return air temperature was 78 degrees. This indicates system is operating properly. Air handler unit coil was dirty. Advise service and clean by HVAC contractor. |
| 15.2 | NORMAL OPERATING CONTROLS
Comments: INSPECTED |
| 15.3 | CONDENSATION LINE OR PUMP'S CONDITION
Comments: INSPECTED |
| 15.4 | DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors)
Comments: INSPECTED |
| 15.5 | PRESENCE OF INSTALLED COOLING SOURCE IN EACH ROOM
Comments: Yes |
| TYPES OF FIREPLACES: MANUFACTURED UNIT | OPERABLE FIREPLACES: ONE |
| 16.0 | FIREPLACE OR SOLID FUEL BURNING DEVICES
Comments: INSPECTED |
| 16.1 | CLEARANCE TO COMBUSTIBLES
Comments: INSPECTED |
| 16.2 | IS THERE A DAMPER
Comments: Yes |
| 16.3 | CONDITION OF HEARTH, MANTLE AND WALL
Comments: INSPECTED |
![]() ProTeam Inspections, Inc.
PO Box 2379 |
|
Customer |
|
Property |
|
This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function, efficiency, or safety of the structure.
This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report.
ROOFING, DRAINAGE, CHIMNEYS
| 1.2 | DOES THE ROOF COVERING APPEAR TO BE IN SERVICEABLE CONDITION
Yes Roof covering is nearing the end of it's life cycle at the "entire roof". Roof covering will need replacing before 5 years. Roof has several missing shingles at rear of roof. Shingles are beginning to curl at edges. Area of roof left of fireplace chase has been repaired. (picture-2) Check with seller for cause. |
| 1.4 | FLASHINGS
INSPECTED Chimney is not flashed properly. Chimney flashing has been placed over surface of siding and caulked. This area will need periodical maintenance. (picture-1) Neoprene flashings around plumbing stacks are worn and require replacing (picture-2). Roof sheathing is discolored around pipe penetrations in attic area. (picture-3) |
| 1.5 | ROOF VENTILATION
INSPECTED Soffit vent screen deteriorated at front of home. |
| 1.6 | SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS
INSPECTED Trim boards at rear of chimney flashing are loose. (picture-1) Wood rot was found at roof level of fireplace chase on right and left sides. This is the result of incorrect flashings (no kickout flashings) at the fireplace chase. (picture-2) Wood rot was found at the back of the fireplace chase just above the Z-flashing joint. (picture-3) |
EAVE, SIDING, FOUNDATION WALLS
| 2.1 | CONDITION OF EXTERIOR WALL COVERINGS
INSPECTED Wood deteriation (wood rot) found as follows: picture 1- Front elevation left side of garage- lap siding above hardy board siding. picture 2- Front elevation right of front door-bottom lap siding above brick sill and widow frame trim boards picture 3- Front elevation left and right areas at front entrance. picture 4- Front elevation left of front entrance-lap siding above brick sill and bottom of window trim. Bottom lap siding behind plants in corner. picture 5- Rear elevation-bottom of right rear window trim board. picture 6- Rear elevation-left bottom corner of door trim. picture 7- Rear elevation-siding has wood rot at bottom at left corner area. picture 8- Hole in wood siding at left side of fireplace chase should be sealed. |
| 2.2 | FOUNDATION WALLS AND MORTAR JOINTS (exterior)
INSPECTED Foundation footer is exposed at right elevation. Advise to add 6-8 inches of soil . |
WINDOWS, DOORS
| 3.0 | OUTSIDE APPEARANCE OF WINDOWS OR SKYLIGHTS
INSPECTED Missing screens |
GARAGE
| 4.2 | CONDITION OF GARAGE DOOR
INSPECTED Garage door has minor bend to top panel rib causing door to bow out. |
DRIVEWAY, RETAINING WALLS, LANDSCAPING
| 5.1 | WALKWAY AND DRIVEWAY
INSPECTED Visible settlement cracks at driveway and rear patio. |
ATTIC AND ROOF STRUCTURE
| 6.1 | IS INSULATION IN ATTIC
Yes Fiberglass (Batts) insulation is about six inches thick or just under 19 R-Value. Fiberglass (loose-fill) insulation is about six inches thick or just under 19 R-Value. Batt insulation displaced at living room knee wall. |
| 6.3 | ARE THERE ANY VISIBLE SIGNS OF LEAKS OR ABNORMAL CONDENSATION
INSPECTED Water signs on plywood resulting from a "Roof leak" found around plumbing exhaust pipe. Recommend repair or replace flashings as needed. |
KITCHEN (Coverings, Windows, Outlets and Doors)
| 7.5 | OUTLETS AND WALL SWITCHES CONDITION
INSPECTED GFCI receptacle left of kitchen sink was inoperative. Advise replacement. |
KITCHEN COMPONENTS, WASHER/DRYER CONNECTIONS
| 8.3 | FAUCET AND SPRAY NOZZLE CONDITION
INSPECTED Faucet is not working properly, and needs repair or replace. Faucet did not have an aerator and spray did not divert correctly. |
| 8.5 | COOKTOP/OVEN OR RANGE OPERATIONAL
INSPECTED Right front burner inoperative |
| 8.8 | ARE THE OUTLETS WITHIN TWO FEET OF THE SINK GFCI
Yes GFCI outlet is defective (grounded, but wont trip with test-plug). |
| 8.12 | WASHER/DRYER CONNECTIONS
INSPECTED Dryer vent is currently venting to interior of garage. It appears the original dryer vent to exterior was abandoned. This mat be due to a clog in vent pipe. |
BEDROOMS (Coverings, Windows, Outlets and Doors)
| 10.3 | DOORS
INSPECTED Front bedroom and master bedroom doors require adjustment. |
HALL BATH
| 11.1.B | WALLS
INSPECTED The tile surround in the hall bathroom was tested with a moisture meter. Elevated levels of moisture was found below the window on the entire back wall of the tub tile surround. Elevated moisture indicates water has found a path to the substrate behind tile. Substrate behind tile covering may be damaged. |
| 11.2.B | FLOORS
INSPECTED Vinyl has moisture stains along bathtub |
BATHROOM COMPONENTS
| 12.1 | CONDITION OF PLUMBING FIXTURES
INSPECTED Hall bath has minor chip in finish under soap dish. Master bath right sink has minor chip to finish. Advise repair. |
Property inspectors are not required to report on the following: Life expectancy of any component or system; The causes of the need for a repair; The methods, materials, and costs of corrections; The suitability of the property for any specialized use; Compliance or non-compliance with codes, ordinances, statutes, regulatory requirements or restrictions; The market value of the property or its marketability; The advisability or inadvisability of purchase of the property; Any component or system that was not observed; The presence or absence of pests such as wood damaging organisms, rodents, or insects; or Cosmetic items, underground items, or items not permanently installed. Property inspectors are not required to: Offer warranties or guarantees of any kind; Calculate the strength, adequacy, or efficiency of any system or component; Enter any area or perform any procedure that may damage the property or its components or be dangerous to the Property inspector or other persons; Operate any system or component that is shut down or otherwise inoperable; Operate any system or component that does not respond to normal operating controls; Disturb insulation, move personal items, panels, furniture, equipment, plant life, soil, snow, ice, or debris that obstructs access or visibility; Determine the presence or absence of any suspected adverse environmental condition or hazardous substance, including but not limited to mold, toxins, carcinogens, noise, contaminants in the building or in soil, water, and air; Determine the effectiveness of any system installed to control or remove suspected hazardous substances; Predict future condition, including but not limited to failure of components; Since this report is provided for the specific benefit of the customer(s), secondary readers of this information should hire a licensed inspector to perform an inspection to meet their specific needs and to obtain current information concerning this property.